USAfixTM - Repair Guide (RG) - Master Email RG
- Check for power to the solution switch
 Level of Difficulty - HIGH  Estimated Completion Time - 10 minutes
TASKI - ERGODISC 200

Tools Required
Tool 
Screwdriver-phillips
Volt meter (True RMS capable)

Parts Required


Step Procedure & Parts & Tools
1 REMOVE THE 6 SCREWS HOLDING THE HANDLE COVER.
Screwdriver-phillips

2 PULL HANDLE COVER FROM MACHINE.

3 PLUG THE MACHINE IN. PULL THE WHITE WIRE AND THE BLACK WIRE FROM THE SOLUTION SWITCH. INSERT RED LEAD INTO THE CONNECTOR ON THE WHITE WIRE AND THE BLACK LEAD INTO THE CONNECTOR ON THE BLACK WIRE. SET THE VOLT METER TO AC VOLTAGE. THE VOLT METER SHOULD READ APPROX. 120 VOLTS. IF METER READS 120 VOLTS, THERE IS POWER TO THE SOLUTION SWITCH. REASSEMBLE HANDLE COVER.
Volt meter (True RMS capable)